Elevator type Thermal Shock Chamber TSD-101-W TSE-12-A (English)


>> P.10

100L2-zonetransitionbyverticaltransferofspecimensTSD-101-WWater-cooled+60℃to+205℃-77℃to0℃±1.0℃+205℃-77℃Within90minfromambienttemp.to+200℃(Setting:+205℃)Within90minfromambienttemp.to-77℃(Setting:-77℃)・Hotexposure:・Coldexposure:・Sensorposition:downstream・Specimen:+150°C(setting:+155°C30min)-65°C(setting:-68°C30min)PlasticmoldedICs,10kgSpecimentemp.within15minWithin10seconds・Hotexposure:・Ambienttemp.:・Specimen:+150℃tomax.+55℃+23℃PlasticmoldedICs,10kgWithin90minShelfbracketson2levels(upto4basketscanbeinstalled)Mechanicalcascaderefrigerationsystem3.73kW(5HP)scroll-type×2R-404A〔R-449Aisavailableonrequest〕,R-23PlatencoolerandcoldaccumulatorPowerslider(250W)USBmemoryport,Ethernetport(LANport),specimenpowersupplycontrolterminal,timesignaloutputterminal(×2),specimentemperatureinputterminal(×2),cableportIDφ100mmonrightside(leftsideavailableasoption),*Powercablesnotincluded.W710×H345×D410mm100L30kgW1100×H1885×D1965mmApprox.1100kg+5℃to+40℃200VAC3φ3W50/60Hz208VAC3φ3W60Hz*6220VAC3φ3W60Hz380VAC3φ4W50Hz400/415VAC3φ4W50Hz*764A62A58A34A32A0.2Mpato0.5Mpa(2kg/cm2Gto5kg/cm2G)2050L/h(atreferencewatertemp.+25℃),3400L/h(atreferencewatertemp.+32℃)Carbonsteelpipe,ID32mm+5℃to+38℃Max.65dB12600kJ/h(3000kcal/h)250m3/h*6ThismodelcomplieswiththerequirementsoftheNationalElectricCode(NFPA70)fortheUnitedStatesofAmerica(NECspec.)ThismodelcomplieswiththerequirementsoftheEuropeanCommunityDirectives(CEspec.)Apressureregulatorvalveisrequiredifthepressureexceeds0.5MPa(5kg/cm2G)Ratedependsonthecleanlinessoftheheatexchanger*7*8*9*10Measurementsaretobetakeninananechoicroomataheightof1.2mfromtheoor,andadistanceof1mfromthefrontpanel(ISO1996-1:2003.A-weightedsoundpressurelevel)HotexposurerangeColdexposurerangeTemp.uctuation*2Pre-heatupperlimitHeat-uptime*3Pre-coollowerlimitPull-downtime*3RecoveryconditionsTSDTestareaHotchamberColdchamberTemp.recoveryperformance(2-zone)Performance*1ModelSystemTemp.recoverytimeTransfertimebetweenhot&coldchambersRecoveryconditionsAmbienttemp.recoverytimeSystemCompressorRefrigerantAmbientrecoveryTestareaRefrigerationunitCoolerElevatingunitFittingsAmbienttemp.rangePowersupply(Voltageuctuation:rating±10%)MaximumloadcurrentCoolingwatersupplypressure*8Coolingwatersupplyrate*9PipingconnectionsizeCoolingwatertemp.rangeUtilityrequirementsInsidedimensionsTestareacapacityLoadcapacityoftestarea*4Outsidedimensions*5WeightNoiselevel*10ExhaustheatrateExhaustairvolume*1Undertheconditionsofa+23℃ambienttemperature,coolingwatertemperature+25℃,ratedvoltage,andnospecimeninsidethetestarea.*2TheperformancevaluesarebasedonIEC60068-3-5:2001,*3Wheneachchamberisoperatedindependently*4Whenusingthetestareaoororheavy-dutyshelves(option)*5ExcludingprotrusionsRoHSdirectiveInternationalstandardsandregionalstandardscomplianceSafetyofMachinery(ISO12100),LowVoltage(IEC60204-1),EMC*(IEC61000-6-2,EN55011).*FortheCE-markedonly.9


<< | < | > | >>