Top : Enviromental Testing Information : Technology Report/Back issue
Technology Report : Keyword Search and subject directory
Adobe Reader Our Technology Reports are readable with an Adobe Reader plug-in. With free Adobe Reader software, you can view and print Adobe PDF files across a broad range of hardware and operating systems.


Subject directory
Some of the articles are available in both English and Japanese. Visit subject directory.

A Environmental Testing
  • A1 Fundamental Concepts of Environmental Testing
  • A2 Accelerated Testing
  • A3 Combined Environmental Testing
  • A4 Product Safety and Failure Analysis
  • A5 Humidity Measurement
  • A6 Environmental Testing Standards
  • A7 Reliability of Printed Circuit Boards
  • A8 Lead-free solder
  • A9 Ionic Migration
  • A10 Reliability of wood materials and Packaging Materials
  • A11 Others
  • B Measurement and Evaluation System
  • Measurement and Evaluation System

    C Burn-in System
  • Burn-in System

    D Life Sciences
  • Life Sciences

    E Agriculture and Biotechnology
  • Agriculture and Biotechnology

    F Ecosystem
  • Ecosystem

    G Fuel Cells
  • Fuel Cells
  • A9 Ionic Migration

    24 (07.5.1) Evaluating the CAF (conductive anodic filament) resistance of multi-layered PWBs

    Abstract
    Advances in the high-density wiring of electronic parts have been accompanied by insulation degradation stemming from ion migration, creating serious problems. While a great deal of research has been carried out investigating the formation of dendrites, which are one form of ion migration, there has been a noticeable lack of clarification of the role of CAF (conductive anodic filament) formation. As a result, we decided to evaluate the CAF resistance of multi-layered PWBs (printed wiring boards). We investigated the relationship between the shape of the CAF that formed and the behavior of insulation resistance levels during CAF formation. We found that during CAF formation the insulation resistance levels repeatedly dropped temporarily and then recovered. In addition, we observed a substance presumed to be CAF at the sites of probable insulation degradation, and we were able to confirm that this substance occurred along the glass fibers.
    Download


    16 (03.10.1) Using the EIS method to analyze the reaction mechanisms of the ionic migration process in solder materials

    Abstract
    Electrochemical impedance spectroscopy (EIS) is attracting attention as an effective method of analyzing electrode interfacial reactions. In this method, a minute AC sine wave signal is overlapped onto a DC signal. The resultant reaction characteristics are then used to analyze the reaction mechanisms. For this report, we used the EIS method to analyze the reaction mechanisms of the migration process in solder materials. The results of this study indicate that the process of ionic migration (also known as electrochemical migration) involves a charge transfer process and a mass transfer process. By monitoring changes in the characteristic values, ionic migration characteristics can be assigned to each type of solder material and used to predict the likelihood of migration occurrence.
    Download


    12 (01.10.1) How impurities affect ionic migration,and how to counter their impact

    Abstract
    The author has studied how impurities adhering to PCBs affect ionic migration, and presents in this report a summary of the results of his investigation.
    Download


    9 (00.4.1) The affects of adsorbed water on printed circuit boards, and the process of ionic migration

    Abstract
    This report considers the insulation resistance characteristics of printed circuit boards (PCBs) and the effects of ionic migration in environmental testing. By measuring insulation resistance in a variety of environmental test conditions, the authors have determined that the initial changes in insulation resistance values is caused by water adsorption*1 and electrolysis. While investigating the occurrence of ionic migration, the authors were able to confirm that metal ions eluted in response to changes in the pH near the electrodes. These changes in pH were determined to have been caused by the electrolysis of water, which affected both pH and applied voltage.
    Download


    4 (97.10.1) Evaluation Mehtod for Ion Migration Using Dew Cycle Test(Part3)

    Abstract
    For our report this time, we have designed prototype experimenting equipment enabling us to directly observe dew condensation conditions, thus allowing us to investigate the causes of Dendrites growing in the Dew Condensation Cycle Test. We have performed experiments to confirm changes in dew condensation conditions and also to confirm the relationship between dew condensation and the growth of Dendrites. At this time, we would like to report on the results of repeated test cycles confirming that water from dew condensation covering the gap between electrodes causes the substrate surface to become subject to wetting and causes Dendrites to grow.
    Download


    2 (96.11.1) A Consideration of Methods for Evaluating Reliability of Electronic Parts-Concerning Methods of Continuously Evaluating Ion Migration-

    Abstract
    Many kinds of testing methods are being explored for use in evaluating reliability. This report examines methods of evaluating reliability of electronic parts and finding the causes of performance degradation and malfunction for which intermittent testing isn't effective. Evaluation is made by continuously measuring insulation resistance of printed circuit boards (PCB) while applying environmental stress, thus monitoring characteristic values throughout the time these values are fluctuating.
    Download


    1 (96.4.1) Evaluation Mehtod for Ion Migration Using Dew Cycle Test(Part1)

    Abstract
    In this paper, we shall present a technical examination of the dew cycle test chamber and actual examples of the evaluation process. We shall also report our findings on the effectiveness of the test chamber.
    Download


    1 (96.4.1) Evaluation Mehtod for Ion Migration Using Dew Cycle Test(Part2)

    Abstract
    In this report (Part 2), we shall discuss how the test chamber has made possible abruptly raising the temperature from a normal temperature range (hereafter called low temperature) to a higher range of temperature and humidity (hereafter called high temperature). The test chamber has also made possible greater fidelity in reproducing the market environment in tests. In addition, we have confirmed the relationship between the speed at which ion migration forms and the quantity of dew condensation forming in the test chamber when temperature and humidity conditions are changed.
    Download


    Copyright ESPEC CORP.All rights reserved.